» KUKA » KRC2 Ed05
KUKA   (312 products)
KRC2 Ed05 Series

UNAVAILABLE

69--000--490 Wieland cable inlet 3 inlets

Ordering information / limitation
The Wieland cable inlet is used in the connector panel of the control cabinet (robot controller).
A cable inlet is necessary if the wiring from the robot controller PC to the connector panel is made by the customer. This is the case if a complete wiring by KUKA is not provided or not desired by the customer.

Two types of Wieland cable inlets can be selected:

Wieland cable inlet with 3 inlets.
Wieland cable inlet including reduction plate and bulkhead-mounted housing; for 3 cables,cable diameter: 2 x 2 - 10 mm + 1 x 9 - 15 mm.

Wieland cable inlet with 4 inlets.
Wieland cable inlet including reduction plate and bulkhead-mounted housing; for 4 cables,cable diameter: 2 x 4,5 - 10 mm + 2 x 9 - 15 mm.

Connector that is necessary for cabling to the PC (with Wieland cable inlet), is not included in delivery.

UNAVAILABLE

UNAVAILABLE

00-151-794 Wieland cable inlet 4 inlets

The Wieland cable inlet is used in the connector panel of the control cabinet (robot controller).
A cable inlet is necessary if the wiring from the robot controller PC to the connector panel is made by the customer. This is the case if a complete wiring by KUKA is not provided or not desired by the customer.

Two types of Wieland cable inlets can be selected:

Wieland cable inlet with 3 inlets.
Wieland cable inlet including reduction plate and bulkhead-mounted housing; for 3 cables,cable diameter: 2 x 2 - 10 mm + 1 x 9 - 15 mm.

Wieland cable inlet with 4 inlets.
Wieland cable inlet including reduction plate and bulkhead-mounted housing; for 4 cables,cable diameter: 2 x 4,5 - 10 mm + 2 x 9 - 15 mm.

Connector that is necessary for cabling to the PC (with Wieland cable inlet), is not included in delivery.

UNAVAILABLE

UNAVAILABLE

00-150-553 DeviceNet Scanner LPDN / PCI

Ordering information / limitation

DevicNet Scanner Card LPDN
- In conjunction with system software KR C V5.2 or higher
- PCI card, 2-channeled CAN-interface with a CAN Controller (SJA 1000) and a 386EX-Microcontroller (33MHz) per channel
- two separately working active channels
- each of the two channels of the LPDN scanner card can be run as master and/or slave
- Baud rate: 125, 250, 500 kBaud
- 2 * 5-pol. Phoenix plug for DeviceNet, external power supply, galvanically isolated

Communication driver
- The communication driver reads and writes data synchronously on the DeviceNet. In addition, it allows the asynchronous transmission of a great amount of data from and to the superimposed controller.
- The communication driver is available on the CD-ROM KUKA.KR C-Upgrade DeviceNet 2.1 and necessary in conjunction with system software KR C V5.4 and higher.
- It is possible to use the function QuickConnect, which allows a quick tool change with changing time of < 500 ms in conjunction with DeviceNet modules on the tool.

KUKA.PLC CIF50 (master card or slave card, Fa. Hilscher)
The Hilscher cards can be used together or independently.
The Hilscher cards can be used only in conjunction with ProConOS, further information see under Software Option / KUKA.PLC.
The Hilscher cards are to be used only with a cable inlet.

The communication driver KR C-Upgrade DeviceNet 2.1 on CD-ROM is for the DeviceNet Scanner card obligatory in conjunction with KUKA system software KR C V5.4, V5.5 and KR C V5.6 .

UNAVAILABLE

UNAVAILABLE

00-181-827 KRC-Upgrade DeviceNet 2.1, CD-ROM

Ordering information / limitation

DevicNet Scanner Card LPDN
- In conjunction with system software KR C V5.2 or higher
- PCI card, 2-channeled CAN-interface with a CAN Controller (SJA 1000) and a 386EX-Microcontroller (33MHz) per channel
- two separately working active channels
- each of the two channels of the LPDN scanner card can be run as master and/or slave
- Baud rate: 125, 250, 500 kBaud
- 2 * 5-pol. Phoenix plug for DeviceNet, external power supply, galvanically isolated

Communication driver
- The communication driver reads and writes data synchronously on the DeviceNet. In addition, it allows the asynchronous transmission of a great amount of data from and to the superimposed controller.
- The communication driver is available on the CD-ROM KUKA.KR C-Upgrade DeviceNet 2.1 and necessary in conjunction with system software KR C V5.4 and higher.
- It is possible to use the function QuickConnect, which allows a quick tool change with changing time of < 500 ms in conjunction with DeviceNet modules on the tool.

KUKA.PLC CIF50 (master card or slave card, Fa. Hilscher)
The Hilscher cards can be used together or independently.
The Hilscher cards can be used only in conjunction with ProConOS, further information see under Software Option / KUKA.PLC.
The Hilscher cards are to be used only with a cable inlet.

The communication driver KR C-Upgrade DeviceNet 2.1 on CD-ROM is for the DeviceNet Scanner card obligatory in conjunction with KUKA system software KR C V5.4, V5.5 and KR C V5.6 .

UNAVAILABLE

UNAVAILABLE

00-123-637 Connector package DeviceNet Scanner LPDN (with terminating resistor)

Ordering information / limitation

DevicNet Scanner Card LPDN
- In conjunction with system software KR C V5.2 or higher
- PCI card, 2-channeled CAN-interface with a CAN Controller (SJA 1000) and a 386EX-Microcontroller (33MHz) per channel
- two separately working active channels
- each of the two channels of the LPDN scanner card can be run as master and/or slave
- Baud rate: 125, 250, 500 kBaud
- 2 * 5-pol. Phoenix plug for DeviceNet, external power supply, galvanically isolated

Communication driver
- The communication driver reads and writes data synchronously on the DeviceNet. In addition, it allows the asynchronous transmission of a great amount of data from and to the superimposed controller.
- The communication driver is available on the CD-ROM KUKA.KR C-Upgrade DeviceNet 2.1 and necessary in conjunction with system software KR C V5.4 and higher.
- It is possible to use the function QuickConnect, which allows a quick tool change with changing time of < 500 ms in conjunction with DeviceNet modules on the tool.

KUKA.PLC CIF50 (master card or slave card, Fa. Hilscher)
The Hilscher cards can be used together or independently.
The Hilscher cards can be used only in conjunction with ProConOS, further information see under Software Option / KUKA.PLC.
The Hilscher cards are to be used only with a cable inlet.

The communication driver KR C-Upgrade DeviceNet 2.1 on CD-ROM is for the DeviceNet Scanner card obligatory in conjunction with KUKA system software KR C V5.4, V5.5 and KR C V5.6 .

UNAVAILABLE

UNAVAILABLE

00-127-854 KUKA.PLC CIF50 DevicenetMaster 1.0, Einsteckkarte

Ordering information / limitation

DevicNet Scanner Card LPDN
- In conjunction with system software KR C V5.2 or higher
- PCI card, 2-channeled CAN-interface with a CAN Controller (SJA 1000) and a 386EX-Microcontroller (33MHz) per channel
- two separately working active channels
- each of the two channels of the LPDN scanner card can be run as master and/or slave
- Baud rate: 125, 250, 500 kBaud
- 2 * 5-pol. Phoenix plug for DeviceNet, external power supply, galvanically isolated

Communication driver
- The communication driver reads and writes data synchronously on the DeviceNet. In addition, it allows the asynchronous transmission of a great amount of data from and to the superimposed controller.
- The communication driver is available on the CD-ROM KUKA.KR C-Upgrade DeviceNet 2.1 and necessary in conjunction with system software KR C V5.4 and higher.
- It is possible to use the function QuickConnect, which allows a quick tool change with changing time of < 500 ms in conjunction with DeviceNet modules on the tool.

KUKA.PLC CIF50 (master card or slave card, Fa. Hilscher)
The Hilscher cards can be used together or independently.
The Hilscher cards can be used only in conjunction with ProConOS, further information see under Software Option / KUKA.PLC.
The Hilscher cards are to be used only with a cable inlet.

The communication driver KR C-Upgrade DeviceNet 2.1 on CD-ROM is for the DeviceNet Scanner card obligatory in conjunction with KUKA system software KR C V5.4, V5.5 and KR C V5.6 .

The KUKA.PLC CIF50 cards can be ordered together or separately.

UNAVAILABLE

UNAVAILABLE

00-128-306 KUKA.PLC CIF50 DevicenetSlave 1.0, Einsteckkarte

Ordering information / limitation

DevicNet Scanner Card LPDN
- In conjunction with system software KR C V5.2 or higher
- PCI card, 2-channeled CAN-interface with a CAN Controller (SJA 1000) and a 386EX-Microcontroller (33MHz) per channel
- two separately working active channels
- each of the two channels of the LPDN scanner card can be run as master and/or slave
- Baud rate: 125, 250, 500 kBaud
- 2 * 5-pol. Phoenix plug for DeviceNet, external power supply, galvanically isolated

Communication driver
- The communication driver reads and writes data synchronously on the DeviceNet. In addition, it allows the asynchronous transmission of a great amount of data from and to the superimposed controller.
- The communication driver is available on the CD-ROM KUKA.KR C-Upgrade DeviceNet 2.1 and necessary in conjunction with system software KR C V5.4 and higher.
- It is possible to use the function QuickConnect, which allows a quick tool change with changing time of < 500 ms in conjunction with DeviceNet modules on the tool.

KUKA.PLC CIF50 (master card or slave card, Fa. Hilscher)
The Hilscher cards can be used together or independently.
The Hilscher cards can be used only in conjunction with ProConOS, further information see under Software Option / KUKA.PLC.
The Hilscher cards are to be used only with a cable inlet.

The communication driver KR C-Upgrade DeviceNet 2.1 on CD-ROM is for the DeviceNet Scanner card obligatory in conjunction with KUKA system software KR C V5.4, V5.5 and KR C V5.6 .

The KUKA.PLC CIF50 cards can be ordered together or separately.

UNAVAILABLE

UNAVAILABLE

00-130-697 Interface DeviceNet (Scanner / Adapter)

Ordering information / limitation

The interfaces show a complete wiring for bus cards in the KUKA robot controller KR C2 edition 2005.
The interface makes it possible to connect user-specific input and output signals to the KR C 2 edition 2005 control cabinet.
The complete wiring offers a quick readiness for operation and substitutes for a customer-specific wiring with cable inlets.
The interfaces differ among other things in use of connectors:
The interface DeviceNet (Scanner / Adapter) has a circular connector.
The interface Multibus-DeviceNet (Adapter) is equipped with a multibus connector.
Please note: Suitable interfaces and bus cards must be selected.
The interfaces with circular connector and multibus connector can be used for the
DeviceNet Scanner card LPDN

UNAVAILABLE

UNAVAILABLE

00-133-495 Interface Multibus-DeviceNet (Adapter)

Ordering information / limitation

The interfaces show a complete wiring for bus cards in the KUKA robot controller KR C2 edition 2005.
The interface makes it possible to connect user-specific input and output signals to the KR C 2 edition 2005 control cabinet.
The complete wiring offers a quick readiness for operation and substitutes for a customer-specific wiring with cable inlets.
The interfaces differ among other things in use of connectors:
The interface DeviceNet (Scanner / Adapter) has a circular connector.
The interface Multibus-DeviceNet (Adapter) is equipped with a multibus connector.
Please note: Suitable interfaces and bus cards must be selected.
The interfaces with circular connector and multibus connector can be used for the
DeviceNet Scanner card LPDN

UNAVAILABLE

UNAVAILABLE

00-108-041 KR C2 X12 interface with I/Os

Ordering information / limitation

For inputs and outputs, the option X12 interface with I/O (via integrated module in the cabinet with X12 cabling) can be ordered.
The X12 interface is sufficient when having a small number of I/Os (16 I/20 Os).

X12 interface with I/Os via CAN module in the cabinet, with X12 wiring

Technical data
- 16 digital inputs (type IEC 1131 - 2)
- 2 groups of 8 inputs
- Common ground
- Programmable filter time

- 16 low-current outputs
- max. 500 mA per output
- 2 groups of 8 outputs
- Shared voltage supply within each group
- Error signaling for each group

- 4 high-current outputs (24 V)
- max. 2 A per output
- Shared ground

- Outputs with external voltage supply and protection against overcurrent, overvoltage, overtemperature and short circuit.

- Inputs and outputs insulated from one another and from the bus

UNAVAILABLE

UNAVAILABLE

00-129-606 Multi-Power Tap MFC 2 (CAN/Devicenet, wiring to DC 24 V)

Ordering information / limitation

The Multi Power Tap is used additionally in conjunction with E/As.
The Multi Power Tap is fixed on the inner side of the cabinet plug board (robot controller KR C2 edition2005).
The Multi Power Tap is a board with two functions:
1. Central power feed for 24V DC voltage for CAN/DeviceNet
2. Star distributor, e.g. for bus line (CAN/DeviceNet from MFC 2 to Multi Power Tap) for extended CAN connection (other applications, further subscribers)
The installation of CAN-bus line and voltage supply is part of the option.,
Advantages for the customer:
Easy connection for bus users (3x CAN-Bus, 2x 24 V DC)
Choice of cable inlet obligatory!

UNAVAILABLE

UNAVAILABLE

00--173--813 KUKA PROFINETCP1616 2.1/ PCI, card

KUKA profinet i/o card: KUKA PROFINET CP 1616

The PC 1616 is a PCI card for connecting PCs to industrial Ethernet.

The KUKA PROFINET CP 1616 offers the following functions and features:
-Configurable and parameterizable across the network.
- Up to 256 devices can be connected to the controller circle
- Connections rated  for 10BASE-T and  100BASE-TX
- Support of data transmission speeds 10 and 100 Mbit/s  in full Duplex and Half Duplex mode.
- Operation of CP 1616 as controller and/or device
- Configuration with step 7 software from Siemens
- Use of acyclic channels
- 4 RJ45 ports for connection of terminals or other network componentes in integrated 4-port real-time switch.
- Coupling/decoupling of devices, e.g. fast tool changer.

 

UNAVAILABLE

UNAVAILABLE

00--193--021 KRC-Upgrade PROFINET 2.3, CD-ROM

KUKA profinet i/o card: KUKA PROFINET CP 1616

The PC 1616 is a PCI card for connecting PCs to industrial Ethernet.

The KUKA PROFINET CP 1616 offers the following functions and features:
-Configurable and parameterizable across the network.
- Up to 256 devices can be connected to the controller circle
- Connections rated  for 10BASE-T and  100BASE-TX
- Support of data transmission speeds 10 and 100 Mbit/s  in full Duplex and Half Duplex mode.
- Operation of CP 1616 as controller and/or device
- Configuration with step 7 software from Siemens
- Use of acyclic channels
- 4 RJ45 ports for connection of terminals or other network componentes in integrated 4-port real-time  switch
- Coupling/decoupling of devices, e.g. fast tool changer.

UNAVAILABLE

UNAVAILABLE

00--166--432 KUKA Ethernet/IP PCU-ETHIO 2.0, board

KUKA Ethernet/IP board: Ethernet/IP PCU-ETHIO 2.0

The Ethernet/IP PCU-ETHIO is a PCI board for connecting PCs to Industrial Ethernet.

The KUKA Ethernet/IP board (CPU-ETHIO) supports the following functions and features:

- Connection type RJ45
- Diferent speeds e.g. automatic, 10 Mbps (in half-and full-duplex modes), 100 Mbps (in half-and full-duplex modes)
- Static TPC/IP configuration via DHCP or BOOTP
- Ethernet/IP scanner and adapter (local slave) functions
- Automatic organization of the input and output memory
- Up to 14 kB on inputs and outputs
- Detailed data transfer
- Equipment support for up to 127 devices and 256 connections
- Multicast, Point to point, real time Format, Trigger, Unique RPI

UNAVAILABLE

UNAVAILABLE

00--166--438 KUKA.KR C-Upgrade Ethernet/IP 2.0, CD-ROM

KUKA Ethernet/IP board: Ethernet/IP PCU-ETHIO 2.0

The Ethernet/IP PCU-ETHIO is a PCI board for connecting PCs to Industrial Ethernet.

The KUKA Ethernet/IP board (CPU-ETHIO) supports the following functions and features:

- Connection type RJ45
- Diferent speeds e.g. automatic, 10 Mbps (in half-and full-duplex modes), 100 Mbps (in half-and full-duplex modes)
- Static TPC/IP configuration via DHCP or BOOTP
- Ethernet/IP scanner and adapter (local slave) functions
- Automatic organization of the input and output memory
- Up to 14 kB on inputs and outputs
- Detailed data transfer
- Equipment support for up to 127 devices and 256 connections
- Multicast, Point to point, real time Format, Trigger, Unique RPI
 

UNAVAILABLE

<< Previos page 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 Next page >>