» KUKA » KRC2 Ed05
KUKA   (312 products)
KRC2 Ed05 Series

No disponible

SafeRobot interface 00-138-890

The SafeRobot interface on the control cabinet offers an additional slot for the second data cable in the connecting cable set Safe, which is necessary for SafeOperation.
The two data cables of the connecting cable set Safe generally connect the safety logic of the KR C2 with the SafeRDC on the robot (see Cross Sectional Technologies / KUKA.SafeRobot / SafeOperation - Axis-specific)

Ordering information / limitation
The cabinet interface SafeRobot is required in conjunction with SafeOperation

No disponible

No disponible

Interbus Copper / PCI , Master/Slave card, Phoenix 00-118-967

Ordering information / limitation
Interbus Copper / PCI, Interbus Master/Slave card from Phoenix, 2 cards combined
Copper wiring The standard connection can be used universally. Currently the most commonly used transmission medium.

- single shield, twisted-pair cables e.g. Li-YCY 3x2x0.25mm
- max. 400 m between two devices without additional repeater.

For the Interbus copper card, the interfaces with circular connector and multibus connector are available.

Interbus optical fiber / PCI, Interbus Master/Slave-Karte from Phoenix, 2 cards combined.
Fiber-optic cables Different duplex fibers can be used:
- Polymer fiber, max. 50m
- HCS fiber, max. 300m
- Glass fiber, max. 3000m.
The Interbus optical fiber card can be used only with a cable inlet!

Features of the Interbus cards
- Range of Application: Automation
- Availability: For KUKA robot controller KR C2 edition2005, from system software KR C V5.2 onwards
- Scope of Delivery: With documentation in German and English (detailed documentation, in particular
EN-standards, see also documentation from Phoenix).

Please note:
The delivery via KUKA makes it possible to integrate the KUKA robot controller into an Interbus System.
KUKA Roboter is not in charge of the complete system.
A diagnostic cable (Interbus configuration tool) and the connector, which is necessary for the cabling to the PC (with Wieland cable inlet) are not part of the scope of delivery

No disponible

No disponible

Interbus optical fiber / PCI, Master/Slave-card from Phoenix 00-118-966

Ordering information / limitation
Interbus Copper / PCI, Interbus Master/Slave card from Phoenix, 2 cards combined
Copper wiring The standard connection can be used universally. Currently the most commonly used transmission medium.

- single shield, twisted-pair cables e.g. Li-YCY 3x2x0.25mm
- max. 400 m between two devices without additional repeater.

For the Interbus copper card, the interfaces with circular connector and multibus connector are available.

Interbus optical fiber / PCI, Interbus Master/Slave-Karte from Phoenix, 2 cards combined.
Fiber-optic cables Different duplex fibers can be used:
- Polymer fiber, max. 50m
- HCS fiber, max. 300m
- Glass fiber, max. 3000m.
The Interbus optical fiber card can be used only with a cable inlet!

Features of the Interbus cards
- Range of Application: Automation
- Availability: For KUKA robot controller KR C2 edition2005, from system software KR C V5.2 onwards
- Scope of Delivery: With documentation in German and English (detailed documentation, in particular
EN-standards, see also documentation from Phoenix).

Please note:
The delivery via KUKA makes it possible to integrate the KUKA robot controller into an Interbus System.
KUKA Roboter is not in charge of the complete system.
A diagnostic cable (Interbus configuration tool) and the connector, which is necessary for the cabling to the PC (with Wieland cable inlet) are not part of the scope of delivery
 

No disponible

No disponible

Interface Interbus (Master / Slave) 00-130-696

Ordering information / limitation
Cabinet interfaces
The interfaces show a complete wiring for bus cards in the KUKA robot controller KR C2 edition2005.
The interface makes it possible to connect user-specific input and output signals to the KR C 2 edition2005
control cabinet.
The complete wiring offers a quick readiness for operation and substitutes for a customer-specific wiring with cable inlets.
The interfaces differ among other things in use of connectors:
The interface Interbus (Master / Slave) has a circular connector.
The interface Multibus-Interbus (Master) is equipped with a multibus connector.
Please note: Suitable interfaces and bus cards must be selected.
The interfaces with circular connector and multibus connector can be used for the
Interbus Copper / PCI , Master/Slave card.
For the Interbus optical fiber / PCI Master/Slave card, there is no interface; it must be used with a cable inlet!

IBS PCI diagnostics cable
The Interbus diagnostics cable is a short connecting cable between the Interbus card and the internal COM2 port. The connection enables the installation of the software diagnostic tool on the control PC and the performance of software diagnosis.
 

No disponible

No disponible

Interface Multibus-Interbus (Master) 00-160-547

Ordering information / limitation
Cabinet interfaces
The interfaces show a complete wiring for bus cards in the KUKA robot controller KR C2 edition2005.
The interface makes it possible to connect user-specific input and output signals to the KR C 2 edition2005
control cabinet.
The complete wiring offers a quick readiness for operation and substitutes for a customer-specific wiring with cable inlets.
The interfaces differ among other things in use of connectors:
The interface Interbus (Master / Slave) has a circular connector.
The interface Multibus-Interbus (Master) is equipped with a multibus connector.
Please note: Suitable interfaces and bus cards must be selected.
The interfaces with circular connector and multibus connector can be used for the
Interbus Copper / PCI , Master/Slave card.
For the Interbus optical fiber / PCI Master/Slave card, there is no interface; it must be used with a cable inlet!

IBS PCI diagnostics cable
The Interbus diagnostics cable is a short connecting cable between the Interbus card and the internal COM2 port. The connection enables the installation of the software diagnostic tool on the control PC and the performance of software diagnosis.

No disponible

No disponible

IBS PCI diagnostics cable 00-116-104

Ordering information / limitation
Cabinet interfaces
The interfaces show a complete wiring for bus cards in the KUKA robot controller KR C2 edition2005.
The interface makes it possible to connect user-specific input and output signals to the KR C 2 edition2005
control cabinet.
The complete wiring offers a quick readiness for operation and substitutes for a customer-specific wiring with cable inlets.
The interfaces differ among other things in use of connectors:
The interface Interbus (Master / Slave) has a circular connector.
The interface Multibus-Interbus (Master) is equipped with a multibus connector.
Please note: Suitable interfaces and bus cards must be selected.
The interfaces with circular connector and multibus connector can be used for the
Interbus Copper / PCI , Master/Slave card.
For the Interbus optical fiber / PCI Master/Slave card, there is no interface; it must be used with a cable inlet!

IBS PCI diagnostics cable
The Interbus diagnostics cable is a short connecting cable between the Interbus card and the internal COM2 port. The connection enables the installation of the software diagnostic tool on the control PC and the performance of software diagnosis.
 

No disponible

No disponible

00-130-764 Profibus card PCI CP 5614 A2

Ordering information / limitation

Profibus Master/Slave (1 card)
- In conjunction with system software KR C V5.2 or higher.
- DP master and DP slave can be operated independently of one another
Master part:

- Optimized for fast DP master operation with up to 122 DP slaves and full data consistency
- Watchdog.

Slave part:
- Modular configuration.
- transfer function for automatic data transfer from the connected DP slave to a higher-level master on the second Profibus segment.

For the Profibus card PCI CP 5614 A2 the interfaces with circular connector, multibus connector and ECOFAST-connector can be used.

KUKA.PLC CIF50 (master card or slave card, Fa. Hilscher)
The Hilscher cards can be used together or independently.
The Hilscher cards can be used only in conjunction with ProConOS, further information see under Software Option / KUKA.PLC. The Hilscher cards are to be used only with a cable inlet.

No disponible

No disponible

Wieland cable inlet with 3 inlests 69--000--490

Ordering information / limitation
The Wieland cable inlet is used in the connector panel of the control cabinet (robot controller).
A cable inlet is necessary if the wiring from the robot controller PC to the connector panel is made by the customer. This is the case if a complete wiring by KUKA is not provided or not desired by the customer.

Two types of Wieland cable inlets can be selected:

Wieland cable inlet with 3 inlets.
Wieland cable inlet including reduction plate and bulkhead-mounted housing; for 3 cables, cable diameter:2 x 2 - 10 mm + 1 x 9 - 15 mm.

Wieland cable inlet with 4 inlets.
Wieland cable inlet including reduction plate and bulkhead-mounted housing; for 4 cables,cable diameter: 2 x 4,5 - 10 mm + 2 x 9 - 15 mm.

Connector that is necessary for cabling to the PC (with Wieland cable inlet), is not included in delivery.

No disponible

No disponible

Wielan cable inlet with 4 inlests 00--151--794

Ordering information / limitation
The Wieland cable inlet is used in the connector panel of the control cabinet (robot controller).
A cable inlet is necessary if the wiring from the robot controller PC to the connector panel is made by the customer. This is the case if a complete wiring by KUKA is not provided or not desired by the customer.

Two types of Wieland cable inlets can be selected:

Wieland cable inlet with 3 inlets.
Wieland cable inlet including reduction plate and bulkhead-mounted housing; for 3 cables, cable diameter:2 x 2 - 10 mm + 1 x 9 - 15 mm.

Wieland cable inlet with 4 inlets.
Wieland cable inlet including reduction plate and bulkhead-mounted housing; for 4 cables,cable diameter: 2 x 4,5 - 10 mm + 2 x 9 - 15 mm.

Connector that is necessary for cabling to the PC (with Wieland cable inlet), is not included in delivery.

No disponible

No disponible

00-127-858 KUKA.PLC CIF50 ProfibusMaster 1.0

Ordering information / limitation

Profibus Master/Slave (1 card)
- In conjunction with system software KR C V5.2 or higher.
- DP master and DP slave can be operated independently of one another
Master part:

- Optimized for fast DP master operation with up to 122 DP slaves and full data consistency
- Watchdog.

Slave part:
- Modular configuration.
- transfer function for automatic data transfer from the connected DP slave to a higher-level master on the second Profibus segment.

For the Profibus card PCI CP 5614 A2 the interfaces with circular connector, multibus connector and ECOFAST-connector can be used.

KUKA.PLC CIF50 (master card or slave card, Fa. Hilscher)
The Hilscher cards can be used together or independently.
The Hilscher cards can be used only in conjunction with ProConOS, further information see under Software Option / KUKA.PLC. The Hilscher cards are to be used only with a cable inlet.

No disponible

No disponible

00-128-307 KUKA.PLC CIF50 ProfibusSlave 1.0

Ordering information / limitation

Profibus Master/Slave (1 card)
- In conjunction with system software KR C V5.2 or higher.
- DP master and DP slave can be operated independently of one another
Master part:

- Optimized for fast DP master operation with up to 122 DP slaves and full data consistency
- Watchdog.

Slave part:
- Modular configuration.
- transfer function for automatic data transfer from the connected DP slave to a higher-level master on the second Profibus segment.

For the Profibus card PCI CP 5614 A2 the interfaces with circular connector, multibus connector and ECOFAST-connector can be used.

KUKA.PLC CIF50 (master card or slave card, Fa. Hilscher)
The Hilscher cards can be used together or independently.
The Hilscher cards can be used only in conjunction with ProConOS, further information see under Software Option / KUKA.PLC. The Hilscher cards are to be used only with a cable inlet.

No disponible

No disponible

00-130-698 Interface Profibus (Master / Slave)

Ordering information / limitation
The interfaces show a complete wiring for fieldbus cards in the KUKA robot controller KR C2 edition 2005.
The interface makes it possible to connect user-specific input and output signals to the KR C 2 edition 2005 control cabinet.
The complete wiring offers a quick readiness for operation and substitutes for a customer-specific wiring with cable inlets.

The interfaces differ among other things in use of connectors:
The interface Profibus (Master/Slave) has a circular connector.
The interface Multibus-Profibus (Master) is equipped with a multibus connector.
The interfaces ECOFAST have ECOFAST-connectors and can be ordered together or separately.

Please note: Suitable interfaces and bus cards must be selected.
The interfaces with circular connector, multibus connector and ECOFAST-connector can be used for the Profibus card PCI C  5614 A2.

No disponible

No disponible

00-160-548 Interface Multibus-Profibus (Master)

Ordering information / limitation
The interfaces show a complete wiring for fieldbus cards in the KUKA robot controller KR C2 edition 2005.
The interface makes it possible to connect user-specific input and output signals to the KR C 2 edition 2005 control cabinet.
The complete wiring offers a quick readiness for operation and substitutes for a customer-specific wiring with cable inlets.

The interfaces differ among other things in use of connectors:
The interface Profibus (Master/Slave) has a circular connector.
The interface Multibus-Profibus (Master) is equipped with a multibus connector.
The interfaces ECOFAST have ECOFAST-connectors and can be ordered together or separately.

Please note: Suitable interfaces and bus cards must be selected.
The interfaces with circular connector, multibus connector and ECOFAST-connector can be used for the Profibus card PCI C  5614 A2.

No disponible

No disponible

00-137-862 Interface ECOFAST Profibus Master

Ordering information / limitation
The interfaces show a complete wiring for fieldbus cards in the KUKA robot controller KR C2 edition 2005.
The interface makes it possible to connect user-specific input and output signals to the KR C 2 edition 2005 control cabinet.
The complete wiring offers a quick readiness for operation and substitutes for a customer-specific wiring with cable inlets.

The interfaces differ among other things in use of connectors:
The interface Profibus (Master/Slave) has a circular connector.
The interface Multibus-Profibus (Master) is equipped with a multibus connector.
The interfaces ECOFAST have ECOFAST-connectors and can be ordered together or separately.

Please note: Suitable interfaces and bus cards must be selected.
The interfaces with circular connector, multibus connector and ECOFAST-connector can be used for the Profibus card PCI C  5614 A2.

No disponible

No disponible

00-137-861 Interface ECOFAST Profibus Slave

Ordering information / limitation
The interfaces show a complete wiring for fieldbus cards in the KUKA robot controller KR C2 edition 2005.
The interface makes it possible to connect user-specific input and output signals to the KR C 2 edition 2005 control cabinet.
The complete wiring offers a quick readiness for operation and substitutes for a customer-specific wiring with cable inlets.

The interfaces differ among other things in use of connectors:
The interface Profibus (Master/Slave) has a circular connector.
The interface Multibus-Profibus (Master) is equipped with a multibus connector.
The interfaces ECOFAST have ECOFAST-connectors and can be ordered together or separately.

Please note: Suitable interfaces and bus cards must be selected.
The interfaces with circular connector, multibus connector and ECOFAST-connector can be used for the Profibus card PCI C  5614 A2.

No disponible

<< Previos page 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 Next page >>