Heat exchanger with small external fan 00--110--820

Use of a heat exchanger is sufficient with an external temperature of up to 45°C, higher temperatures( up to 50°C), an additional cooling unit must be used (see under cooling unit). the minimum permissible ambient temperature for operation of the KR C2 (with/without cooling unit) is +5°C.

Ordering information / limitations

A selection must be made between "heat exchanger with small external fan" and " heat exchanger with large external fan". the heat exchanger with small external fan is  suitable for low to high payloads (KR 6 to KR 240-2 and variants).

The heat extranger with large external fan must be selected

- for  heavy-duty robots (KR 360 and larger);

- if an external axis is is used with KUKA servo drive KSD1-64 in the basic cabinet;

- if a top-mounted cabinet is used.

UNAVAILABLE

UNAVAILABLE

Heat exchanger with large external fan 00--110--821

Use of a heat exchanger is sufficient with an external temperature of up to 45°C, higher temperatures( up to 50°C), an additional cooling unit must be used (see under cooling unit). the minimum permissible ambient temperature for operation of the KR C2 (with/without cooling unit) is +5°C.

Ordering information / limitations

A selection must be made between "heat exchanger with small external fan" and " heat exchanger with large external fan". the heat exchanger with small external fan is  suitable for low to high payloads (KR 6 to KR 240-2 and variants).

The heat extranger with large external fan must be selected

- for  heavy-duty robots (KR 360 and larger);

- if an external axis is is used with KUKA servo drive KSD1-64 in the basic cabinet;

- if a top-mounted cabinet is used.

UNAVAILABLE

UNAVAILABLE

Fork Slots 00--107--951

To simplify transportation, fork slots and/or sets of rollers are mounted directly on the cabinet.

the rollers, which allow the cabinet to be maneuvered easily, are available in two sizes 75mm and 125mm diameter).

Ordering information

if a transformer with underslung box is used, the fork slots and rollers are already integrated  and  need not be selected here.

UNAVAILABLE

UNAVAILABLE

For

To simplify transportation, fork slots and/or sets of rollers are mounted directly on the cabinet.
The rollers, which allow the cabinet to be maneuvered easily, are available in two sizes
(75 mm and 125 mm diameter

Ordering information
If a transformer with underslung box is used, the fork slots and rollers are already integrated and
need not be selected here!

UNAVAILABLE

UNAVAILABLE

Fork slots, stainless steel 00-118-930

To simplify transportation, fork slots and/or sets of rollers are mounted directly on the cabinet.
The rollers, which allow the cabinet to be maneuvered easily, are available in two sizes
(75 mm and 125 mm diameter).
Ordering information
If a transformer with underslung box is used, the fork slots and rollers are already integrated and
need not be selected here!

UNAVAILABLE

UNAVAILABLE

Set of rollers, 75 mm, on the cabinet feet (fork slots) 00-125-204

To simplify transportation, fork slots and/or sets of rollers are mounted directly on the cabinet.

the rollers, which allow the cabinet to be maneuvered easily, are available in two sizes 75mm and 125mm diameter).

Ordering information

if a transformer with underslung box is used, the fork slots and rollers are already integrated  and  need not be selected here.

UNAVAILABLE

UNAVAILABLE

Set of rollers on the cabinet, 125 mm 00-116-413

To simplify transportation, fork slots and/or sets of rollers are mounted directly on the cabinet.

the rollers, which allow the cabinet to be maneuvered easily, are available in two sizes 75mm and 125mm diameter).

Ordering information

if a transformer with underslung box is used, the fork slots and rollers are already integrated  and  need not be selected here.

UNAVAILABLE

UNAVAILABLE

Service socket AC 230 V before main switch 00-115-633

The service socket serves as a power source for test and diagnosis equipment.
In the “upstream of main switch” variants, the sockets are active even when the main power switch is
turned off. An N-conductor must also be connected.
In the “from transformer” variants, the sockets are only active if the main power switch is turned on.
A ground-fault circuit interrupter must be selected if plant regulations or regulations of the power utility
concerned stipulate that a ground-fault circuit interrupter is required for socket-outlet circuits.
The ground-fault circuit interrupters are tripped by residual currents of 10 mA.
The socket must not be used as a permanent power source for external devices.

 

UNAVAILABLE

UNAVAILABLE

Service socket AC 230 V before main switch with RCCB 00-107-501

The service socket serves as a power source for test and diagnosis equipment.
In the “upstream of main switch” variants, the sockets are active even when the main power switch is
turned off. An N-conductor must also be connected.
In the “from transformer” variants, the sockets are only active if the main power switch is turned on.
A ground-fault circuit interrupter must be selected if plant regulations or regulations of the power utility
concerned stipulate that a ground-fault circuit interrupter is required for socket-outlet circuits.
The ground-fault circuit interrupters are tripped by residual currents of 10 mA.
The socket must not be used as a permanent power source for external devices.

UNAVAILABLE

UNAVAILABLE

Service socket AC 230 V from transformer with RCCB 00-107-503

The service socket serves as a power source for test and diagnosis equipment.
In the “upstream of main switch” variants, the sockets are active even when the main power switch is
turned off. An N-conductor must also be connected.
In the “from transformer” variants, the sockets are only active if the main power switch is turned on.
A ground-fault circuit interrupter must be selected if plant regulations or regulations of the power utility
concerned stipulate that a ground-fault circuit interrupter is required for socket-outlet circuits.
The ground-fault circuit interrupters are tripped by residual currents of 10 mA.
The socket must not be used as a permanent power source for external devices.

UNAVAILABLE

UNAVAILABLE

Service socket AC 110 V from transformer 00-115-065

The service socket serves as a power source for test and diagnosis equipment.
In the “upstream of main switch” variants, the sockets are active even when the main power switch is
turned off. An N-conductor must also be connected.
In the “from transformer” variants, the sockets are only active if the main power switch is turned on.
A ground-fault circuit interrupter must be selected if plant regulations or regulations of the power utility
concerned stipulate that a ground-fault circuit interrupter is required for socket-outlet circuits.
The ground-fault circuit interrupters are tripped by residual currents of 10 mA.
The socket must not be used as a permanent power source for external devices.
 

UNAVAILABLE

UNAVAILABLE

Cabinet interior lamp AC 230 V before main switch 00-107-505

The control cabinet can be fitted with a cabinet interior lamp.
The “cabinet interior lamp AC 230 V before main switch” is active even when the main power switch is
turned off.
If the cabinet is supplied with power from a transformer or a 24 V power supply, the lamp is only active
when the main switch is turned on.
The lamp is turned on and off by means of a door switch.

UNAVAILABLE

<< Previos page 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 Next page >>